Menu
June 1, 2021  |  

Full-length isoform sequencing of the human MCF-7 cell line using PacBio long reads.

While advances in RNA sequencing methods have accelerated our understanding of the human transcriptome, isoform discovery remains a challenge because short read lengths require complicated assembly algorithms to infer the contiguity of full-length transcripts. With PacBio’s long reads, one can now sequence full-length transcript isoforms up to 10 kb. The PacBio Iso- Seq protocol produces reads that originate from independent observations of single molecules, meaning no assembly is needed. Here, we sequenced the transcriptome of the human MCF-7 breast cancer cell line using the Clontech SMARTer® cDNA preparation kit and the PacBio RS II. Using PacBio Iso-Seq bioinformatics software, we obtained 55,770 unique, full-length, high-quality transcript sequences that were subsequently mapped back to the human genome with = 99% accuracy. In addition, we identified both known and novel fusion transcripts. To assess our results, we compared the predicted ORFs from the PacBio data against a published mass spectrometry dataset from the same cell line. 84% of the proteins identified with the Uniprot protein database were recovered by the PacBio predictions. Notably, 251 peptides solely matched to the PacBio generated ORFs and were entirely novel, including abundant cases of single amino acid polymorphisms, cassette exon splicing and potential alternative protein coding frames.


June 1, 2021  |  

Assembly of complete KIR haplotypes from a diploid individual by the direct sequencing of full-length fosmids.

We show that linearizing and directly sequencing full-length fosmids simplifies the assembly problem such that it is possible to unambiguously assemble individual haplotypes for the highly repetitive 100-200 kb killer Ig-like receptor (KIR) gene loci of chromosome 19. A tiling of targeted fosmids can be used to clone extended lengths of genomic DNA, 100s of kb in length, but repeat complexity in regions of particular interest, such as the KIR locus, means that sequence assembly of pooled samples into complete haplotypes is difficult and in many cases impossible. The current maximum read length generated by SMRT Sequencing exceeds the length of a 40 kb fosmid; it is therefore possible to span an entire fosmid in one sequencing read. Shearing, sequencing and assembling fosmids in a shotgun approach is prone to errors when the underlying sequence is highly repetitive. We show that it is possible to directly sequence linearized fosmids and generate a high-quality consensus by simple alignment, removing the need for an error-prone assembly step. The high-quality sequence of complete fosmids can then be tiled into full haplotypes. We demonstrate the method on DNA samples from a number of individuals and fully recover the sequence of both haplotypes from a pool of KIR fosmids. The ability to haplotype and sequence complex immunogenetic regions will bring exciting opportunities to explore the evolution of disease associations of the immune sub-genome. This simple and robust approach can be scaled-up allowing a complex genomic region to be sequenced at a population level. We expect such sequencing to be valuable in disease association research.


June 1, 2021  |  

Highly contiguous de novo human genome assembly and long-range haplotype phasing using SMRT Sequencing

The long reads, random error, and unbiased sampling of SMRT Sequencing enables high quality, de novo assembly of the human genome. PacBio long reads are capable of resolving genomic variations at all size scales, including SNPs, insertions, deletions, inversions, translocations, and repeat expansions, all of which are important in understanding the genetic basis for human disease and difficult to access via other technologies. In demonstration of this, we report a new high-quality, diploid aware de novo assembly of Craig Venter’s well-studied genome.


June 1, 2021  |  

Low-input long-read sequencing for complete microbial genomes and metagenomic community analysis.

Microbial genome sequencing can be done quickly, easily, and efficiently with the PacBio sequencing instruments, resulting in complete de novo assemblies. Alternative protocols have been developed to reduce the amount of purified DNA required for SMRT Sequencing, to broaden applicability to lower-abundance samples. If 50-100 ng of microbial DNA is available, a 10-20 kb SMRTbell library can be made. A 2 kb SMRTbell library only requires a few ng of gDNA when carrier DNA is added to the library. The resulting libraries can be loaded onto multiple SMRT Cells, yielding more than enough data for complete assembly of microbial genomes using the SMRT Portal assembly program HGAP, plus base-modification analysis. The entire process can be done in less than 3 days by standard laboratory personnel. This approach is particularly important for the analysis of metagenomic communities, in which genomic DNA is often limited. From these samples, full-length 16S amplicons can be generated, prepped with the standard SMRTbell library prep protocol, and sequenced. Alternatively, a 2 kb sheared library, made from a few ng of input DNA, can also be used to elucidate the microbial composition of a community, and may provide information about biochemical pathways present in the sample. In both these cases, 1-2 kb reads with >99% accuracy can be obtained from Circular Consensus Sequencing.


June 1, 2021  |  

Barcoding strategies for multiplexing of samples using a long-read sequencing technology.

We have developed barcoding reagents and workflows for multiplexing amplicons or fragmented native genomic (DNA) prior to Single Molecule, Real-Time (SMRT) Sequencing. The long reads of PacBio’s SMRT Sequencing enable detection of linked mutations across multiple kilobases (kb) of sequence. This feature is particularly useful in the context of mutational analysis or SNP confirmation, where a large number of samples are generated routinely. To validate this workflow, a set of 384 1.7-kb amplicons, each derived from variants of the Phi29 DNA polymerase gene, were barcoded during amplification, pooled, and sequenced on a single SMRT Cell. To demonstrate the applicability of the method to longer inserts, a library of 96 5-kb clones derived from the E. coli genome was sequenced.


June 1, 2021  |  

Profiling metagenomic communities using circular consensus and Single Molecule, Real-Time Sequencing.

There are many sequencing-based approaches to understanding complex metagenomic communities spanning targeted amplification to whole-sample shotgun sequencing. While targeted approaches provide valuable data at low sequencing depth, they are limited by primer design and PCR amplification. Whole-sample shotgun experiments generally use short-read, second-generation sequencing, which results in data processing difficulties. For example, reads less than 1 kb in length will likely not cover a complete gene or region of interest, and will require assembly. This not only introduces the possibility of incorrectly combining sequence from different community members, it requires a high depth of coverage. As such, rare community members may not be represented in the resulting assembly. Circular-consensus, single molecule, real-time (SMRT) Sequencing reads in the 1-2 kb range, with >99% accuracy can be efficiently generated for low amounts of input DNA. 10 ng of input DNA sequenced in 4 SMRT Cells would generate >100,000 such reads. While throughput is low compared to second-generation sequencing, the reads are a true random sampling of the underlying community, since SMRT Sequencing has been shown to have no sequence-context bias. Long read lengths mean that that it would be reasonable to expect a high number of the reads to include gene fragments useful for analysis.


June 1, 2021  |  

Analysis of full-length metagenomic 16S genes by Single Molecule, Real-Time Sequencing

High-throughput sequencing of the complete 16S rRNA gene has become a valuable tool for characterizing microbial communities. However, the short reads produced by second-generation sequencing cannot provide taxonomic classification below the genus level. In this study, we demonstrate the capability of PacBio’s Single Molecule, Real-Time (SMRT) Sequencing to generate community profiles using mock microbial community samples from BEI Resources. We also evaluate multiplexing capabilities using PacBio barcodes on pooled samples comprising heterogeneous 16S amplicon populations representing soil, fecal, and mock communities.


June 1, 2021  |  

Full-length sequencing of HLA class I genes of more than 1000 samples provides deep insights into sequence variability

Aim: The vast majority of donor typing relies on sequencing exons 2 and 3 of HLA class I genes (HLA-A, -B, -C). With such an approach certain allele combinations do not result in the anticipated “high resolution” (G-code) typing, due to the lack of exon-phasing information. To resolve ambiguous typing results for a haplotype frequency project, we established a whole gene sequencing approach for HLA class I, facilitating also an estimation of the degree of sequence variability outside the commonly sequenced exons. Methods: Primers were developed flanking the UTR regions resulting in similar amplicon lengths of 4.2-4.4 kb. Using a 4-primer approach, secondary primers containing barcodes were combined with the gene specific primers to obtain barcoded full-gene amplicons in a single amplification step. Amplicons were pooled, purified, and ligated to SMRT bells (i.e. annealing points for sequencing primers) following standard protocols from Pacific Biosciences. Taking advantage of the SMRT chemistry, pools of 48-72 amplicons were sequenced full length and phased in single runs on a Pacific Biosciences RSII instrument. Demultiplexing was achieved using the SMRT portal. Sequence analysis was performed using NGSengine software (GenDx). Results: We successfully performed full-length gene sequencing of 1003 samples, harboring ambiguous typings of either HLA-A (n=46), HLA-B (n=304) or HLA-C (n=653). Despite the high per-read raw error rates typical for SMRT sequencing (~15%) the consensus sequence proved highly reliable. All consensus sequences for exons 2 and 3 were in full accordance with their MiSeq-derived sequences. Unambiguous allelic resolution was achieved for all samples. We observed novel intronic, exonic as well as UTR sequence variations for many of the alleles covered by our data set. This included sequences of 600 individuals with HLA-C*07:01/C*07:02 genotype revealing the extent of sequence variation outside the exons 2 and 3. Conclusion: Here we present a whole gene amplification and sequencing approach for HLA class I genes. The maturity of this approach was demonstrated by sequencing more than 1000 samples, achieving fully phased allelic sequences. Extensive sequencing of one common allele combination hints at the yet to discover diversity of the HLA system outside the commonly analyzed exons.


June 1, 2021  |  

Phased full-length SMRT Sequencing of HLA DPB1

Aim: In contrast to exon-based HLA-typing approaches, whole gene genotyping crucially depends on full-length sequences submitted to the IMGT/HLA Database. Currently, full-length sequences are provided for only 7 out of 520 HLA-DPB1 alleles. Therefore, we developed a fully phased whole-gene sequencing approach for DPB1, to facilitate further exploration of the allelic structure at this locus. Methods: Primers were developed flanking the UTR-regions of DPB1 resulting in a 12 kb amplicon. Using a 4-primer approach, secondary primers containing barcodes were combined with the gene-specific primers to obtain barcoded full-gene amplicons in a single amplification step. Amplicons were pooled, purified, and ligated to SMRT bells (i.e. annealing points for sequencing primers) following standard protocols from Pacific Biosciences. Taking advantage of the SMRT chemistry, pools of 48 amplicons were sequenced full length in single runs on a Pacific Biosciences RSII instrument. Demultiplexing was performed using the SMRT portal. Sequence analysis was performed using the NGSengine software (GenDx). Results: We analyzed a set of 48 randomly picked samples. With 3 exceptions due to PCR failure, all genotype assignments conformed to standard genotyping results based on exons 2 and 3. Allelic proportions for heterozygous positions were evenly distributed (range 0.4 – 0.6) for all samples, suggesting unbiased amplifications. Despite the high per-read raw error rates typical for SMRT sequencing (~15%) the consensus sequence proved highly reliable. All consensus sequences for exons 2 and 3 were in full accordance with their MiSeq-derived sequences. We describe novel intronic sequence variation of the 7 so far genomically defined alleles, as well as 7 whole-length DPB1 alleles with hitherto unknown intronic regions. One of these alleles (HLA-DPB1*131:01) is classified as rare. Conclusion: Here we present a whole gene amplification and sequencing workflow for DPB1 alleles utilizing single molecule real-time (SMRT) sequencing from Pacific Biosciences. Validation of consensus sequences against known exonic sequences highlights the reliability of this technology. This workflow will facilitate amending the IMGT/HLA Database for DPB1.


June 1, 2021  |  

Access full spectrum of polymorphisms in HLA class I & II genes, without imputation for disease association and evolutionary research.

MHC class I and II genes are critically monitored by high-resolution sequencing for organ transplant decisions due to their role in GVHD. Their direct or linkage-based causal association, have increased their prominence as targets for drug sensitivity, autoimmune, cancer and infectious disease research. Monitoring HLA genes can however be tricky due to their highly polymorphic nature. Allele-level resolution is thus strongly preferred. However, most studies were historically focused on peptide binding domains of the HLA genes, due to technological challenges. As a result knowledge about the functional role of polymorphisms outside of exons 2 and 3 of HLA genes was rather limited. There are also relatively few full-length gene references currently available in the IMGT HLA database. This made it difficult to quickly adopt high-throughput reference-reliant methods for allele-level HLA sequencing. Increasing awareness regarding role of regulatory region polymorphisms of HLA genes in disease association1, nonetheless have brought about a revolution in full-length HLA gene sequencing. Researchers are now exploring ways to obtain complete information for HLA genes and integrate it with the current HLA database so it can be interpreted used by clinical researchers. We have explored advantages of SMRT Sequencing to obtain fully phased, allele-specific sequences of HLA class I and II genes for 96 samples using completely De novo consensus generation approach for imputation-free 4-field typing. With long read lengths (average >10 kb) and consensus accuracy exceeding 99.999% (Q50), a comprehensive snapshot of variants in exons, introns and UTRs could be obtained for spectrum of polymorphisms in phase across SNP-poor regions. Such information can provide invaluable insights in future causality association and population diversity research.


June 1, 2021  |  

Full-length cDNA sequencing of alternatively spliced isoforms provides insight into human cancer

The majority of human genes are alternatively spliced, making it possible for most genes to generate multiple proteins. The process of alternative splicing is highly regulated in a developmental-stage and tissue-specific manner. Perturbations in the regulation of these events can lead to disease in humans (1). Alternative splicing has been shown to play a role in human cancer, muscular dystrophy, Alzheimer’s, and many other diseases. Understanding these diseases requires knowing the full complement of mRNA isoforms. Microarrays and high-throughput cDNA sequencing have become highly successful tools for studying transcriptomes, however these technologies only provide small fragments of transcripts and building complete transcript isoforms has been very challenging (2). We have developed a technique, called Iso-Seq sequencing, that is capable of sequencing full-length, single-molecule cDNA sequences. The method employs SMRT Sequencing from PacBio, which can sequence individual molecules with read lengths that average more than 10 kb and can reach as long as 40 kb. As most transcripts are from 1 – 10 kb, we can sequence through entire RNA molecules, requiring no fragmentation or post-sequencing assembly. Jointly with the sequencing method, we developed a computational pipeline that polishes these full-length transcript sequences into high-quality, non-redundant transcript consensus sequences. Iso-Seq sequencing enables unambiguous identification of alternative splicing events, alternative transcriptional start and polyA sites, and transcripts from gene fusion events. Knowledge of the complete set of isoforms from a sample of interest is key for accurate quantification of isoform abundance when using any technology for transcriptome studies (3). Here we characterize the full-length transcriptome of paired tumor/normal samples from breast cancer using deep Iso-Seq sequencing. We highlight numerous discoveries of novel alternatively spliced isoforms, gene-fusion events, and previously unannotated genes that will improve our understanding of human cancer. (1) Faustino NA and Cooper TA. Genes and Development. 2003. 17: 419-437(2) Steijger T, et al. Nat Methods. 2013 Dec;10(12):1177-84.(3) Au KF, et al. Proc Natl Acad Sci U S A. 2013 Dec 10;110(50):E4821-30.


June 1, 2021  |  

Comprehensive genome and transcriptome structural analysis of a breast cancer cell line using PacBio long read sequencing

Genomic instability is one of the hallmarks of cancer, leading to widespread copy number variations, chromosomal fusions, and other structural variations. The breast cancer cell line SK-BR-3 is an important model for HER2+ breast cancers, which are among the most aggressive forms of the disease and affect one in five cases. Through short read sequencing, copy number arrays, and other technologies, the genome of SK-BR-3 is known to be highly rearranged with many copy number variations, including an approximately twenty-fold amplification of the HER2 oncogene. However, these technologies cannot precisely characterize the nature and context of the identified genomic events and other important mutations may be missed altogether because of repeats, multi-mapping reads, and the failure to reliably anchor alignments to both sides of a variation. To address these challenges, we have sequenced SK-BR-3 using PacBio long read technology. Using the new P6-C4 chemistry, we generated more than 70X coverage of the genome with average read lengths of 9-13kb (max: 71kb). Using Lumpy for split-read alignment analysis, as well as our novel assembly-based algorithms for finding complex variants, we have developed a detailed map of structural variations in this cell line. Taking advantage of the newly identified breakpoints and combining these with copy number assignments, we have developed an algorithm to reconstruct the mutational history of this cancer genome. From this we have discovered a complex series of nested duplications and translocations between chr17 and chr8, two of the most frequent translocation partners in primary breast cancers, resulting in amplification of HER2. We have also carried out full-length transcriptome sequencing using PacBio’s Iso-Seq technology, which has revealed a number of previously unrecognized gene fusions and isoforms. Combining long-read genome and transcriptome sequencing technologies enables an in-depth analysis of how changes in the genome affect the transcriptome, including how gene fusions are created across multiple chromosomes. This analysis has established the most complete cancer reference genome available to date, and is already opening the door to applying long-read sequencing to patient samples with complex genome structures.


June 1, 2021  |  

Profiling metagenomic communities using circular consensus and Single Molecule, Real-Time Sequencing

There are many sequencing-based approaches to understanding complex metagenomic communities, spanning targeted amplification to whole-sample shotgun sequencing. While targeted approaches provide valuable data at low sequencing depth, they are limited by primer design and PCR amplification. Whole-sample shotgun experiments require a high depth of coverage. As such, rare community members may not be represented in the resulting assembly. Circular-consensus, Single Molecule, Real-Time (SMRT) Sequencing reads in the 1-2 kb range, with >99% consensus accuracy, can be efficiently generated for low amounts of input DNA, e.g. as little as 10 ng of input DNA sequenced in 4 SMRT Cells can generate >100,000 such reads. While throughput is low compared to second-generation sequencing, the reads are a true random sampling of the underlying community. Long read lengths translate to a high number of the reads harboring full genes or even full operons for downstream analysis. Here we present the results of circular-consensus sequencing on a mock metagenomic community with an abundance range of multiple orders of magnitude, and compare the results with both 16S and shotgun assembly methods. We show that even with relatively low sequencing depth, the long-read, assembly-free, random sampling allows to elucidate meaningful information from the very low-abundance community members. For example, given the above low-input sequencing approach, a community member at 1/1,000 relative abundance would generate 100 1-2 kb sequence fragments having 99% consensus accuracy, with a high probability of containing a gene fragment useful for taxonomic classification or functional insight.


Talk with an expert

If you have a question, need to check the status of an order, or are interested in purchasing an instrument, we're here to help.