Comprehensive variant detection in a human genome with PacBio high-fidelity reads

Human genomic variations range in size from single nucleotide substitutions to large chromosomal rearrangements. Sequencing technologies tend to be optimized for detecting particular variant types and sizes. Short reads excel at detecting SNVs and small indels, while long or linked reads are typically used to detect larger structural variants or phase distant loci. Long reads are more easily mapped to repetitive regions, but tend to have lower per-base accuracy, making it difficult to call short variants. The PacBio Sequel System produces two main data types: long continuous reads (up to 100 kbp), generated by single passes over a long template, and Circular Consensus Sequence (CCS) reads, generated by calculating the consensus of many sequencing passes over a single shorter template (500 bp to 20 kbp). The long-range information in continuous reads is useful for genome assembly and structural variant detection. The higher base accuracy of CCS effectively detects and phases short variants in single molecules. Recent improvements in library preparation protocols and sequencing chemistry have increased the length, accuracy, and throughput of CCS reads. For the human sample HG002, we collected 28-fold coverage 15 kbp high-fidelity CCS reads with an average read quality above Q20 (99% accuracy). The length and accuracy of these reads allow us to detect SNVs, indels, and structural variants not only in the Genome in a Bottle (GIAB) high confidence regions, but also in segmental duplications, HLA loci, and clinically relevant “difficult-to-map” genes. As with continuous long reads, we call structural variants at 90.0% recall compared to the GIAB structural variant benchmark “truth” set, with the added advantages of base pair resolution for variant calls and improved recall at compound heterozygous loci. With minimap2 alignments, GATK4 HaplotypeCaller variant calls, and simple variant filtration, we have achieved a SNP F-Score of 99.51% and an INDEL F-Score of 80.10% against the GIAB short variant benchmark “truth” set, in addition to calling variants outside of the high confidence region established by GIAB using previous technologies. With the long-range information available in 15 kbp reads, we applied the read-backed phasing tool WhatsHap to generate phase blocks with a mean length of 65 kbp across the entire genome. Using an alignment-based approach, we typed all major MHC class I and class II genes to at least 3-field precision. This new data type has the potential to expand the GIAB high confidence regions and “truth” benchmark sets to many previously difficult-to-map genes and allow a single sequencing protocol to address both short variants and large structural variants.


June 1, 2021

A low DNA input protocol for high-quality PacBio de novo genome assemblies from single invertebrate individuals

A high-quality reference genome is an essential tool for studies of plant and animal genomics. PacBio Single Molecule, Real-Time (SMRT) Sequencing generates long reads with uniform coverage and high consensus accuracy, making it a powerful technology for de novo genome assembly. PacBio is the core technology for many large genome initiatives, however, relatively high DNA input requirements (5 µg for standard library protocol) have placed PacBio out of reach for many projects on small, non-inbred organisms that may have lower DNA content. Here we present high-quality de novo genome assemblies from single invertebrate individuals for two different species: the Anopheles coluzzii mosquito and the Schistosoma mansoni parasitic flatworm. A modified SMRTbell library construction protocol without DNA shearing and size selection was used to generate a SMRTbell library from just 50-100 ng of starting genomic DNA. The libraries were run on the Sequel System with chemistry v3.0 and software v6.0, generating a range of 21-32 Gb of sequence per SMRT Cell with 20 hour movies, and followed by diploid de novo genome assembly with FALCON-Unzip. The resulting assemblies had high contiguity (contig N50s over 3 Mb for both species) and completeness (as determined by conserved BUSCO gene analysis). We were also able to resolve maternal and paternal haplotypes for 1/3 of the genome in both cases. By sequencing and assembling material from a single diploid individual, only two haplotypes are present, simplifying the assembly process compared to samples from multiple pooled individuals. This new low-input approach puts PacBio-based assemblies in reach for small, highly heterozygous organisms that comprise much of the diversity of life. The method presented here can be applied to samples with starting DNA amounts around 100 ng per 250 Mb – 1 Gb genome size.


June 1, 2021

Single molecule high-fidelity (HiFi) Sequencing with >10 kb libraries

Recent improvements in sequencing chemistry and instrument performance combine to create a new PacBio data type, Single Molecule High-Fidelity reads (HiFi reads). Increased read length and improvement in library construction enables average read lengths of 10-20 kb with average sequence identity greater than 99% from raw single molecule reads. The resulting reads have the accuracy comparable to short read NGS but with 50-100 times longer read length. Here we benchmark the performance of this data type by sequencing and genotyping the Genome in a Bottle (GIAB) HG0002 human reference sample from the National Institute of Standards and Technology (NIST). We further demonstrate the general utility of HiFi reads by analyzing multiple clones of Cabernet Sauvignon. Three different clones were sequenced and de novo assembled with the CANU assembly algorithm, generating draft assemblies of very high contiguity equal to or better than earlier assembly efforts using PacBio long reads. Using the Cabernet Sauvignon Clone 8 assembly as a reference, we mapped the HiFi reads generated from Clone 6 and Clone 47 to identify single nucleotide polymorphisms (SNPs) and structural variants (SVs) that are specific to each of the three samples.


June 1, 2021

A high-quality de novo genome assembly from a single mosquito using PacBio sequencing

A high-quality reference genome is an essential tool for studies of plant and animal genomics. PacBio Single Molecule, Real-Time (SMRT) Sequencing generates long reads with uniform coverage and high consensus accuracy, making it a powerful technology for de novo genome assembly. While PacBio is the core technology for many large genome initiatives, relatively high DNA input requirements (3 µg for standard library protocol) have placed PacBio out of reach for many projects on small, non-inbred organisms that may have lower DNA content. Here we present high-quality de novo genome assemblies from single invertebrate individuals for two different species: the Anopheles coluzzii mosquito and the Schistosoma mansoni parasitic flatworm. A modified SMRTbell library construction protocol without DNA shearing and size selection was used to generate a SMRTbell library from just 150 ng of starting genomic DNA. The libraries were run on the Sequel System with chemistry v3.0 and software v6.0, generating a range of 21-32 Gb of sequence per SMRT Cell with 20-hour movies (10-12 Gb for 10-hour movies), and followed by diploid de novo genome assembly with FALCON-Unzip. The resulting assemblies had high contiguity (contig N50s over 3 Mb for both species) and completeness (as determined by conserved BUSCO gene analysis). We were also able to resolve maternal and paternal haplotypes for 1/3 of the genome in both cases. By sequencing and assembling material from a single diploid individual, only two haplotypes are present, simplifying the assembly process compared to samples from multiple pooled individuals. This new low-input approach puts PacBio-based assemblies in reach for small, highly heterozygous organisms that comprise much of the diversity of life. The method presented here can be applied to samples with starting DNA amounts around 150 ng per 250 Mb – 600 Mb genome size.


June 1, 2021

Streamlines SMRTbell library generation using addition-only, single tube strategy for all library types reduces time to results

We have streamlined the SMRTbell library generation protocols with improved workflows to deliver seamless end-to-end solutions from sample to analysis. A key improvement is the development of a single-tube reaction strategy that shortened hands-on time needed to generate each SMRTbell library, reduced time-consuming AM Pure purification steps, and minimized sample-handling induced gDNA damage to improve the integrity of long-insert SMRTbell templates for sequencing. The improved protocols support all large-insert genomic libraries, multiplexed microbial genomes, and amplicon sequencing. These advances enable completion of library preparation in less than a day (approximately 4 hours) and opens opportunities for automated library preparation for large-scale projects. Here we share data summarizing performance of the new SMRTbell Express Template Kit 2.0 representing our solutions for 10 kb and >50 kb large-insert genomic libraries, complete microbial genome assemblies, and high-throughput amplicon sequencing. The improved throughput of the Sequel System with read lengths up to 30 kb and high consensus accuracy (> 99.999% accuracy) makes sequencing with high-quality results increasingly assessible to the community.


June 1, 2021

A low DNA input protocol for high-quality PacBio de novo genome assemblies

A high-quality reference genome is an essential tool for studying the genetics of traits and disease, organismal, comparative and conservation biology, and population genomics. PacBio Single Molecule, Real-Time (SMRT) Sequencing generates long reads with uniform coverage and high consensus accuracy, making it a powerful technology for de novo genome assembly. Improvements in throughput and concomitant reductions in cost have made PacBio an attractive core technology for many large genome initiatives. However, relatively high DNA input requirements (3 µg for standard library protocol) have placed PacBio out of reach for many projects on small organisms that may have lower DNA content or on projects with limited input DNA for other reasons. Here we present a modified SMRTbell library construction protocol without DNA shearing or size selection that can be used to generate a SMRTbell library from just 150 ng of starting genomic DNA. Remarkably, the protocol enables high quality de novo assemblies from single invertebrate individuals and is applied to taxonomically diverse samples. By sequencing and assembling material from a single diploid individual, only two haplotypes are present, simplifying the assembly process compared to samples from multiple pooled individuals. The libraries were run on the Sequel System with chemistry v3.0 and software v6.0, generating ~11 Gb of sequence per SMRT Cell with 10 hour movies, and followed by de novo genome assembly with FALCON. The resulting assemblies had high contiguity (contig N50s over 1 Mb) and completeness (as determined by conserved BUSCO gene analysis) when at least 30-fold unique molecular coverage is obtained. This new low-input approach now puts PacBio-based assemblies in reach for small highly heterozygous organisms that comprise much of the diversity of life. The method presented here is scalable and can be applied to samples with starting DNA amounts of 150 ng per 300 Mb genome size.


June 1, 2021

Structural variant detection with long read sequencing reveals driver and passenger mutations in a melanoma cell line

Past large scale cancer genome sequencing efforts, including The Cancer Genome Atlas and the International Cancer Genome Consortium, have utilized short-read sequencing, which is well-suited for detecting single nucleotide variants (SNVs) but far less reliable for detecting variants larger than 20 base pairs, including insertions, deletions, duplications, inversions and translocations. Recent same-sample comparisons of short- and long-read human reference genome data have revealed that short-read resequencing typically uncovers only ~4,000 structural variants (SVs, =50 bp) per genome and is biased towards deletions, whereas sequencing with PacBio long-reads consistently finds ~20,000 SVs, evenly balanced between insertions and deletions. This discovery has important implications for cancer research, as it is clear that SVs are both common and biologically important in many cancer subtypes, including colorectal, breast and ovarian cancer. Without confident and comprehensive detection of structural variants, it is unlikely we have a sufficiently complete picture of all the genomic changes that impact cancer development, disease progression, treatment response, drug resistance, and relapse. To begin to address this unmet need, we have sequenced the COLO829 tumor and matched normal lymphoblastoid cell lines to 49- and 51-fold coverage, respectively, with PacBio SMRT Sequencing, with the goal of developing a high-confidence structural variant call set that can be used to empirically evaluate cost-effective experimental designs for larger scale studies and develop structural variation calling software suitable for cancer genomics. Structural variant calling revealed over 21,000 deletions and 19,500 insertions larger than 20 bp, nearly four times the number of events detected with short-read sequencing. The vast majority of events are shared between the tumor and normal, with about 100 putative somatic deletions and 400 insertions, primarily in microsatellites. A further 40 rearrangements were detected, nearly exclusively in the tumor. One rearrangement is shared between the tumor and normal, t(5;X) which disrupts the mismatch repeat gene MSH3, and is likely a driver mutation. Generating high-confidence call sets that cover the entire size-spectrum of somatic variants from a range of cancer model systems is the first step in determining what will be the best approach for addressing an ongoing blind spot in our current understanding of cancer genomes. Here the application of PacBio sequencing to a melanoma cancer cell line revealed thousands of previously overlooked variants, including a mutation likely involved in tumorogenesis.


June 1, 2021

Comprehensive variant detection in a human genome with highly accurate long reads

Introduction: Long-read sequencing has been applied successfully to assemble genomes and detect structural variants. However, due to high raw-read error rates (10-15%), it has remained difficult to call small variants from long reads. Recent improvements in library preparation and sequencing chemistry have increased length, accuracy, and throughput of PacBio circular consensus sequencing (CCS) reads, resulting in 10-20kb reads with average read quality above 99%. Materials and Methods: We sequenced a 12kb library from human reference sample HG002 to 18-fold coverage on the PacBio Sequel II System with three SMRT Cells 8M. The CCS algorithm was used to generate highly-accurate (average 99.8%) 11.4kb reads, which were mapped to the hg19 reference with pbmm2. We detected small variants using Google DeepVariant with a model trained for CCS and phased the variants using WhatsHap. Structural variants were detected with pbsv. Variant calls were evaluated against Genome in a Bottle (GIAB) benchmarks. Results: With these reads, DeepVariant achieves SNP and Indel F1 scores of 99.82% and 96.70% against the GIAB truth set, and pbsv achieves 95.94% recall on structural variants longer than 50bp. Using WhatsHap, small variants were phased into haplotype blocks with 105kb N50. The improved mappability of long reads allows us to align to and detect variants in medically relevant genes such as CYP2D6 and PMS2 that have proven “difficult-to-map” with short reads. Conclusions: These highly-accurate long reads combine the mappability and ability to detect structural variants of long reads with the accuracy and ability to detect small variants of short reads.


June 1, 2021

Structural variant detection in crops using low-fold coverage long-read sequencing

Genomics studies have shown that the insertions, deletions, duplications, translocations, inversions, and tandem repeat expansions in the structural variant (SV) size range (>50 bp) contribute to the evolution of traits and often have significant associations with agronomically important phenotypes. However, most SVs are too small to detect with array comparative genomic hybridization and too large to reliably discover with short-read DNA sequencing. While de novo assembly is the most comprehensive way to identify variants in a genome, recent studies in human genomes show that PacBio SMRT Sequencing sensitively detects structural variants at low coverage. Here we present SV characterization in the major crop species Oryza sativa subsp. indica (rice) with low-fold coverage of long reads. In addition, we provide recommendations for sequencing and analysis for the application of this workflow to other important agricultural species.


June 1, 2021

High-quality human genomes achieved through HiFi sequence data and FALCON-Unzip assembly

De novo assemblies of human genomes from accurate (85-90%), continuous long reads (CLR) now approach the human reference genome in contiguity, but the assembly base pair accuracy is typically below QV40 (99.99%), an order-of-magnitude lower than the standard for finished references. The base pair errors complicate downstream interpretation, particularly false positive indels that lead to false gene loss through frameshifts. PacBio HiFi sequence data, which are both long (>10 kb) and very accurate (>99.9%) at the individual sequence read level, enable a new paradigm in human genome assembly. Haploid human assemblies using HiFi data achieve similar contiguity to those using CLR data and are highly accurate at the base level1. Furthermore, HiFi assemblies resolve more high-identity sequences such as segmental duplications2. To enable HiFi assembly in diploid human samples, we have extended the FALCON-Unzip assembler to work directly with HiFi reads. Here we present phased human diploid genome assemblies from HiFi sequencing of HG002, HG005, and the Vertebrate Genome Project (VGP) mHomSap1 trio on the PacBio Sequel II System. The HiFi assemblies all exceed the VGP’s quality guidelines, approaching QV50 (99.999%) accuracy. For HG002, 60% of the genome was haplotype-resolved, with phase-block N50 of 143Kbp and phasing accuracy of 99.6%. The overall mean base accuracy of the assembly was QV49.7. In conclusion, HiFi data show great promise towards complete, contiguous, and accurate diploid human assemblies.


June 1, 2021

Every species can be a model: Reference-quality PacBio genomes from single insects

A high-quality reference genome is an essential resource for primary and applied research across the tree of life. Genome projects for small-bodied, non-model organisms such as insects face several unique challenges including limited DNA input quantities, high heterozygosity, and difficulty of culturing or inbreeding in the lab. Recent progress in PacBio library preparation protocols, sequencing throughput, and read accuracy address these challenges. We present several case studies including the Red Admiral (Vanessa atalanta), Monarch Butterfly (Danaus plexippus), and Anopheles malaria mosquitoes that highlight the benefits of sequencing single individuals for de novo genome assembly projects, and the ease at which these projects can be conducted by individual research labs. Sampled individuals may originate from lab colonies of interest to the research community or be sourced from the wild to better capture natural variation in a focal population. Where genomic DNA quantities are limited, the PacBio Low DNA Input Protocol requires ~100 ng of input DNA. Low DNA input samples with 500 Mb genome size or less can be multiplexed on a single SMRT Cell 8M on the Sequel II System. For samples with more abundant DNA quantity, size-selected libraries may be constructed to maximize sequencing yield. Both low DNA input and size-selected libraries can be used to generate HiFi reads, whose quality is Q20 or above (1% error or less) and lengths range from 10 – 25 kb. With HiFi reads, de novo assembly computation is greatly simplified relative to long read methods due to smaller sequence file sizes and more rapid analysis, resulting in highly accurate, contiguous, complete, and haplotype-resolved assemblies.


June 1, 2021

Beyond Contiguity: Evaluating the accuracy of de novo genome assemblies

HiFi reads (>99% accurate, 15-20 kb) from the PacBio Sequel II System consistently provide complete and contiguous genome assemblies. In addition to completeness and contiguity, accuracy is of critical importance, as assembly errors complicate downstream analysis, particularly by disrupting gene frames. Metrics used to assess assembly accuracy include: 1) in-frame gene count, 2) kmer consistency, and 3) concordance to a benchmark, where discordances are interpreted as assembly errors. Genome in a Bottle (GIAB) provides a benchmark for the human genome with estimated accuracy of 99.9999% (Q60). Concordance for human HiFi assemblies exceeds Q50, which provides excellent genomes for downstream analysis, but presents a challenge that any new benchmark must significantly exceed Q50 or the discordance will represent the error rate of the benchmark. To establish benchmarks for Oryza sativa and Drosophila melanogaster, we collected draft references, Illumina short reads, and PacBio HiFi reads. By species, the benchmark was defined as regions of normal coverage that are not within 5 bp of a small variant or 50 bp of a structural variant. For both species, the benchmark regions span around 60% of the genome and HiFi assemblies achieve Q50 accuracy, which is notably more accurate than assemblies with other technologies and meets typical standards for a finished, reference-grade assembly. Here we present a protocol to generate benchmarks for any sample that rival the GIAB benchmark in accuracy. These benchmarks allow the comparison and improvement of genome assemblies and highlight the superior accuracy of assemblies generated with PacBio HiFi reads.


June 1, 2021

A high-quality PacBio insect genome from 5 ng of input DNA

High-quality insect genomes are essential resources to understand insect biology and to combat them as disease vectors and agricultural pests. It is desirable to sequence a single individual for a reference genome to avoid complications from multiple alleles during de novo assembly. However, the small body size of many insects poses a challenge for the use of long-read sequencing technologies which often have high DNA-input requirements. The previously described PacBio Low DNA Input Protocol starts with ~100 ng of DNA and allows for high-quality assemblies of single mosquitoes among others and represents a significant step in reducing such requirements. Here, we describe a new library protocol with a further 20-fold reduction in the DNA input quantity. Starting with just 5 ng of high molecular weight DNA, we describe the successful sequencing and de novo genome assembly of a single male sandfly (Phlebotomus papatasi, the main vector of the Old World cutaneous leishmaniasis), using HiFi data generated on the PacBio Sequel II System and assembled with FALCON. The assembly shows a high degree of completeness (>97% of BUSCO genes are complete), contiguity (contig N50 of 1 Mb), and sequence accuracy (>98% of BUSCO genes without frameshift errors). This workflow has general utility for small-bodied insects and other plant and animal species for both focused research studies or in conjunction with large-scale genome projects.


June 1, 2021

New advances in SMRT Sequencing facilitate multiplexing for de novo and structural variant studies

The latest advancements in Sequel II SMRT Sequencing have increased average read lengths up to 50% compared to Sequel II chemistry 1.0 which allows multiplexing of 2-3 small organisms (<500 Mb) such as insects and worms for producing reference quality assemblies, calling structural variants for up to 2 samples with ~3 Gb genomes, analysis of 48 microbial genomes, and up to 8 communities for metagenomic profiling in a single SMRT Cell 8M. With the improved processivity of the new Sequel II sequencing polymerase, more SMRTbell molecules reach rolling circle mode resulting in longer overall read lengths, thus allowing efficient detection of barcodes (up to 80%) in the SMRTbell templates. Multiplexing of genomes larger than microbial organisms is now achievable. In collaboration with the Wellcome Sanger Institute, we have developed a workflow for multiplexing two individual Anopheles coluzzii using as low as 150 ng genomic DNA per individual. The resulting assemblies had high contiguity (contig N50s over 3 Mb) and completeness (>98% of conserved genes) for both individuals. For microbial multiplexing, we multiplexed 48 microbes with varying complexities and sizes ranging 1.6-8.0 Mb in single SMRT Cell 8M. Using a new end-to-end analysis (Microbial Assembly Analysis, SMRT Link 8.0), assemblies resulted in complete circularized genomes (>200-fold coverage) and efficient detection of >3-200 kb plasmids. Finally, the long read lengths (>90 kb) allows detection of barcodes in large insert SMRTbell templates (>15 kb) thus facilitating multiplex of two human samples in 1 SMRT Cell 8M for detecting SVs, Indels and CNVs. Here, we present results and describe workflows for multiplexing samples for specific applications for SMRT Sequencing.


June 1, 2021

Improving long-read assembly of microbial genomes and plasmids

Complete, high-quality microbial genomes are very valuable across a broad array of fields, from environmental studies, to human microbiome health, food pathogen surveillance, etc. Long-read sequencing enables accurate resolution of complex microbial genomes and is becoming the new standard. Here we report our novel Microbial Assembly pipeline to facilitate rapid, large-scale analysis of microbial genomes. We sequenced a 48-plex library with one SMRT Cell 8M on the Sequel II System, demultiplexed, then analyzed the data with Microbial Assembly.


Talk with an expert

If you have a question, need to check the status of an order, or are interested in purchasing an instrument, we're here to help.