Menu
June 1, 2021  |  

A high-quality de novo genome assembly from a single mosquito using PacBio sequencing

A high-quality reference genome is an essential tool for studies of plant and animal genomics. PacBio Single Molecule, Real-Time (SMRT) Sequencing generates long reads with uniform coverage and high consensus accuracy, making it a powerful technology for de novo genome assembly. While PacBio is the core technology for many large genome initiatives, relatively high DNA input requirements (3 µg for standard library protocol) have placed PacBio out of reach for many projects on small, non-inbred organisms that may have lower DNA content. Here we present high-quality de novo genome assemblies from single invertebrate individuals for two different species: the Anopheles coluzzii mosquito and the Schistosoma mansoni parasitic flatworm. A modified SMRTbell library construction protocol without DNA shearing and size selection was used to generate a SMRTbell library from just 150 ng of starting genomic DNA. The libraries were run on the Sequel System with chemistry v3.0 and software v6.0, generating a range of 21-32 Gb of sequence per SMRT Cell with 20-hour movies (10-12 Gb for 10-hour movies), and followed by diploid de novo genome assembly with FALCON-Unzip. The resulting assemblies had high contiguity (contig N50s over 3 Mb for both species) and completeness (as determined by conserved BUSCO gene analysis). We were also able to resolve maternal and paternal haplotypes for 1/3 of the genome in both cases. By sequencing and assembling material from a single diploid individual, only two haplotypes are present, simplifying the assembly process compared to samples from multiple pooled individuals. This new low-input approach puts PacBio-based assemblies in reach for small, highly heterozygous organisms that comprise much of the diversity of life. The method presented here can be applied to samples with starting DNA amounts around 150 ng per 250 Mb – 600 Mb genome size.


June 1, 2021  |  

Streamlines SMRTbell library generation using addition-only, single tube strategy for all library types reduces time to results

We have streamlined the SMRTbell library generation protocols with improved workflows to deliver seamless end-to-end solutions from sample to analysis. A key improvement is the development of a single-tube reaction strategy that shortened hands-on time needed to generate each SMRTbell library, reduced time-consuming AM Pure purification steps, and minimized sample-handling induced gDNA damage to improve the integrity of long-insert SMRTbell templates for sequencing. The improved protocols support all large-insert genomic libraries, multiplexed microbial genomes, and amplicon sequencing. These advances enable completion of library preparation in less than a day (approximately 4 hours) and opens opportunities for automated library preparation for large-scale projects. Here we share data summarizing performance of the new SMRTbell Express Template Kit 2.0 representing our solutions for 10 kb and >50 kb large-insert genomic libraries, complete microbial genome assemblies, and high-throughput amplicon sequencing. The improved throughput of the Sequel System with read lengths up to 30 kb and high consensus accuracy (> 99.999% accuracy) makes sequencing with high-quality results increasingly assessible to the community.


June 1, 2021  |  

A low DNA input protocol for high-quality PacBio de novo genome assemblies

A high-quality reference genome is an essential tool for studying the genetics of traits and disease, organismal, comparative and conservation biology, and population genomics. PacBio Single Molecule, Real-Time (SMRT) Sequencing generates long reads with uniform coverage and high consensus accuracy, making it a powerful technology for de novo genome assembly. Improvements in throughput and concomitant reductions in cost have made PacBio an attractive core technology for many large genome initiatives. However, relatively high DNA input requirements (3 µg for standard library protocol) have placed PacBio out of reach for many projects on small organisms that may have lower DNA content or on projects with limited input DNA for other reasons. Here we present a modified SMRTbell library construction protocol without DNA shearing or size selection that can be used to generate a SMRTbell library from just 150 ng of starting genomic DNA. Remarkably, the protocol enables high quality de novo assemblies from single invertebrate individuals and is applied to taxonomically diverse samples. By sequencing and assembling material from a single diploid individual, only two haplotypes are present, simplifying the assembly process compared to samples from multiple pooled individuals. The libraries were run on the Sequel System with chemistry v3.0 and software v6.0, generating ~11 Gb of sequence per SMRT Cell with 10 hour movies, and followed by de novo genome assembly with FALCON. The resulting assemblies had high contiguity (contig N50s over 1 Mb) and completeness (as determined by conserved BUSCO gene analysis) when at least 30-fold unique molecular coverage is obtained. This new low-input approach now puts PacBio-based assemblies in reach for small highly heterozygous organisms that comprise much of the diversity of life. The method presented here is scalable and can be applied to samples with starting DNA amounts of 150 ng per 300 Mb genome size.


June 1, 2021  |  

Full-length transcriptome sequencing of melanoma cell line complements long-read assessment of genomic rearrangements

Transcriptome sequencing has proven to be an important tool for understanding the biological changes in cancer genomes including the consequences of structural rearrangements. Short read sequencing has been the method of choice, as the high throughput at low cost allows for transcript quantitation and the detection of even rare transcripts. However, the reads are generally too short to reconstruct complete isoforms. Conversely, long-read approaches can provide unambiguous full-length isoforms, but lower throughput has complicated quantitation and high RNA input requirements has made working with cancer samples challenging. Recently, the COLO 829 cell line was sequenced to 50-fold coverage with PacBio SMRT Sequencing. To validate and extend the findings from this effort, we have generated long-read transcriptome data using an updated PacBio Iso-Seq method, the results of which will be shared at the AACR 2019 General Meeting. With this complimentary transcriptome data, we demonstrate how recent innovations in the PacBio Iso-Seq method sample preparation and sequencing chemistry have made long-read sequencing of cancer transcriptomes more practical. In particular, library preparation has been simplified and throughput has increased. The improved protocol has reduced sample prep time from several days to one day while reducing the sample input requirements ten-fold. In addition, the incorporation of unique molecular identifier (UMI) tags into the workflow has improved the bioinformatics analysis. Yield has also increased, with v3 sequencing chemistry typically delivering > 30 Gb per SMRT Cell 1M. By integrating long and short read data, we demonstrate that the Iso-Seq method is a practical tool for annotating cancer genomes with high-quality transcript information.


June 1, 2021  |  

Comparison of sequencing approaches applied to complex soil metagenomes to resolve proteins of interest

Background: Long-read sequencing presents several potential advantages for providing more complete gene profiling of metagenomic samples. Long reads can capture multiple genes in a single read, and longer reads typically result in assemblies with better contiguity, especially for higher abundance organisms. However, a major challenge with using long reads has been the higher cost per base, which may lead to insufficient coverage of low-abundance species. Additionally, lower single-pass accuracy can make gene discovery for low-abundance organisms difficult. Methods: To evaluate the pros and cons of long reads for metagenomics, we directly compared PacBio and Illumina sequencing on a soil-derived sample, which included spike-in controls of known concentrations of pure referenced samples. For PacBio sequencing, a 10 kb library was sequenced on the Sequel System with 3.0 chemistry. Highly accurate long reads (HiFi reads) with Q20 and higher were generated for downstream analyses using PacBio Circular Consensus Sequencing (CCS) mode. Results were assessed according to the following criteria: DNA extraction capacity, bioinformatics pipeline status, % of proteins with ambiguous AA’s, total unique error-free genes/$1000, total proteins observed in spike-ins/$1000, proteins of interest/$1000, median length of contigs with proteins, and assembly requirements. Results: Both methods had areas of superior performance. DNA extraction capacity was higher for Illumina, the bioinformatics pipeline is well-tested, and there was a lower proportion of proteins with ambiguous AA’s. On the other hand, with PacBio, twice as many unique error-free genes, twice as many total proteins from spike-ins, and ~6 times more proteins of interest were found per $1000 cost. PacBio data produced on average 5 times longer contigs capturing proteins of interest. Additionally, assembly was not required for gene or protein finding, as was the case with Illumina data. Conclusions: In this comparison of PacBio Sequel System with Illumina NextSeq on a complex microbiome, we conclude that the sequencing system of choice may vary, depending on the goals and resources for the project. PacBio sequencing requires a longer DNA extraction method, and the bioinformatics pipeline may require development. On the other hand, the Sequel System generates hundreds of thousands of long HiFi reads per SMRT Cell, producing more genes, more proteins, and longer contigs, thereby offering more information about the metagenomic samples for a lower cost.


June 1, 2021  |  

Unbiased characterization of metagenome composition and function using HiFi sequencing on the PacBio Sequel II System

Recent work comparing metagenomic sequencing methods indicates that a comprehensive picture of the taxonomic and functional diversity of complex communities will be difficult to achieve with short-read technology alone. While the lower cost of short reads has enabled greater sequencing depth, the greater contiguity of long-read assemblies and lack of GC bias in SMRT Sequencing has enabled better gene finding. However, since long-read assembly requires high coverage for error correction, the benefits of unbiased coverage have in the past been lost for low abundance species. SMRT Sequencing performance improvements and the introduction of the Sequel II System has enabled a new, high throughput data type uniquely suited to metagenome characterization: HiFi reads. HiFi reads combine high accuracy with read lengths up to 15 kb, eliminating the need for assembly for most microbiome applications, including functional profiling, gene discovery, and metabolic pathway reconstruction. Here we present the application of the HiFi data type to enable a new method of analyzing metagenomes that does not require assembly.


June 1, 2021  |  

Sequencing the previously unsequenceable using amplification-free targeted enrichment powered by CRISPR/Cas9

Genomic regions with extreme base composition bias and repetitive sequences have long proven challenging for targeted enrichment methods, as they rely upon some form of amplification. Similarly, most DNA sequencing technologies struggle to faithfully sequence regions of low complexity. This has especially been true for repeat expansion disorders such as Fragile X syndrome, Huntington’s disease and various Ataxias, where the repetitive elements range from several hundreds of bases to tens of kilobases. We have developed a robust, amplification-free targeted enrichment technique, called No-Amp Targeted Sequencing, that employs the CRISPR/Cas9 system. In conjunction with Single Molecule, Real-Time (SMRT) Sequencing, which delivers long reads spanning the entire repeat expansion, high consensus accuracy, and uniform coverage, these previously inaccessible regions are now accessible. This method is completely amplification-free, therefore removing any PCR errors and biases from the experiment. Furthermore, this technique also preserves native DNA molecules, allowing for direct detection and characterization of epigenetic signatures. The No-Amp method is a two-day protocol, compatible with multiplexing of multiple targets and samples in a single reaction, using as little as 1 µg of genomic DNA input per sample. We have successfully targeted a number of repeat expansion disorder loci (HTT, FMR1, ATXN10, C9orf72) with alleles as long as >2700 repeat unites (>13 kb). Using the No-Amp method we have isolated hundreds of individual on-target molecules, allowing for reliable repeat size estimation, mosaicism detection and identification of interruption sequences – all aspects of repeat expansion disorders which are important for better understanding the underlying disease mechanisms.


June 1, 2021  |  

TLA & long-read sequencing: Efficient targeted sequencing and phasing of the CFTR gene

Background: The sequencing and haplotype phasing of entire gene sequences improves the understanding of the genetic basis of disease and drug response. One example is cystic fibrosis (CF). Cystic fibrosis transmembrane conductance regulator (CFTR) modulator therapies have revolutionized CF treatment, but only in a minority of CF subjects. Observed heterogeneity in CFTR modulator efficacy is related to the range of CFTR mutations; revertant mutations can modify the response to CFTR modulators, and other intronic variations in the ~200 kb CFTR gene have been linked to disease severity. Heterogeneity in the CFTR gene may also be linked to differential responses to CFTR modulators. The Targeted Locus Amplification (TLA) technology from Cergentis can be used to selectively amplify, sequence and phase the entire CFTR gene. With PacBio long-read SMRT Sequencing, TLA amplicons are sequenced intact and long-range phasing information of all fragments in entire amplicons is retrieved. Experimental Design and Methods: The TLA process produces amplicons consisting of 5-10 proximity ligated DNA fragments. TLA was performed on cell line and genomic DNA from Coriell GM12878, which has few heterozygous SNVs in CFTR, and the IB3 cell line, with known haplotypes but heterozygous for the delta508 mutation. All sample types were prepared with high and low density TLA primer sets, targeting coverage of >100 kb of the CFTR gene. Conclusion: We have demonstrated the power and utility of TLA with long-read SMRT Sequencing as a valuable research tool in sequencing and phasing across very long regions of the human genome. This process can be done in an efficient manner, multiplexing multiple genes and samples per SMRT Cell in a process amenable to high-throughput sequencing.


June 1, 2021  |  

Full-Length RNA-seq of Alzheimer brain on the PacBio Sequel II System

The PacBio Iso-Seq method produces high-quality, full-length transcripts and can characterize a whole transcriptome with a single SMRT Cell 8M. We sequenced an Alzheimer whole brain sample on a single SMRT Cell 8M on the Sequel II System. Using the Iso-Seq bioinformatics pipeline followed by SQANTI2 analysis, we detected 162,290 transcripts for 17,670 genes up to 14 kb in length. More than 60% of the transcripts are novel isoforms, the vast majority of which have supporting cage peak data and polyadenylation signals, demonstrating the utility of long-read sequencing for human disease research.


June 1, 2021  |  

Every species can be a model: Reference-quality PacBio genomes from single insects

A high-quality reference genome is an essential resource for primary and applied research across the tree of life. Genome projects for small-bodied, non-model organisms such as insects face several unique challenges including limited DNA input quantities, high heterozygosity, and difficulty of culturing or inbreeding in the lab. Recent progress in PacBio library preparation protocols, sequencing throughput, and read accuracy address these challenges. We present several case studies including the Red Admiral (Vanessa atalanta), Monarch Butterfly (Danaus plexippus), and Anopheles malaria mosquitoes that highlight the benefits of sequencing single individuals for de novo genome assembly projects, and the ease at which these projects can be conducted by individual research labs. Sampled individuals may originate from lab colonies of interest to the research community or be sourced from the wild to better capture natural variation in a focal population. Where genomic DNA quantities are limited, the PacBio Low DNA Input Protocol requires ~100 ng of input DNA. Low DNA input samples with 500 Mb genome size or less can be multiplexed on a single SMRT Cell 8M on the Sequel II System. For samples with more abundant DNA quantity, size-selected libraries may be constructed to maximize sequencing yield. Both low DNA input and size-selected libraries can be used to generate HiFi reads, whose quality is Q20 or above (1% error or less) and lengths range from 10 – 25 kb. With HiFi reads, de novo assembly computation is greatly simplified relative to long read methods due to smaller sequence file sizes and more rapid analysis, resulting in highly accurate, contiguous, complete, and haplotype-resolved assemblies.


June 1, 2021  |  

A complete solution for high-quality genome annotation using the PacBio Iso-Seq method

The PacBio Iso-Seq method produces high-quality, full-length transcripts of up to 10 kb and longer and has been used to annotate many important plant and animal genomes. We describe here the full Iso-Seq ecosystem that enables researchers to achieve high-quality genome annotations. The Iso-Seq Express workflow is a 1-day protocol that requires only 60-300 ng of total RNA and supports multiplexing of different tissues. Sequencing on a single SMRT Cell 8M on the Sequel II System produces up to 4 million full-length reads, sufficient to exhaustively characterize a whole transcriptome on the order of 15,000-17,000 genes with 100,000 or more transcripts. Most importantly, the method is supported by a maturing suite of official and community-developed tools. The SMRT Link Iso-Seq application outputs high-quality (>99% accurate), full-length transcript sequences that can optionally be mapped to a reference genome for a single SMRT Cell worth of data in 6-9 hours. For example, the SQANTI2 tool classifies Iso-Seq transcripts against a reference annotation, filters potential library artifacts, and processes information from both long read-only and short read-based quantification. IsoPhase is a tool for identifying allele-specific isoform expression. Cogent has been used to process Iso-Seq transcripts in a genome-independent manner to assess genome assemblies. Finally, IsoAnnot is an up-and-coming tool for identifying differential isoform expression across different samples. We describe how these tools complement each other and provide guidelines to make the best use out of Iso-Seq data for understanding transcriptomes.


June 1, 2021  |  

A high-quality PacBio insect genome from 5 ng of input DNA

High-quality insect genomes are essential resources to understand insect biology and to combat them as disease vectors and agricultural pests. It is desirable to sequence a single individual for a reference genome to avoid complications from multiple alleles during de novo assembly. However, the small body size of many insects poses a challenge for the use of long-read sequencing technologies which often have high DNA-input requirements. The previously described PacBio Low DNA Input Protocol starts with ~100 ng of DNA and allows for high-quality assemblies of single mosquitoes among others and represents a significant step in reducing such requirements. Here, we describe a new library protocol with a further 20-fold reduction in the DNA input quantity. Starting with just 5 ng of high molecular weight DNA, we describe the successful sequencing and de novo genome assembly of a single male sandfly (Phlebotomus papatasi, the main vector of the Old World cutaneous leishmaniasis), using HiFi data generated on the PacBio Sequel II System and assembled with FALCON. The assembly shows a high degree of completeness (>97% of BUSCO genes are complete), contiguity (contig N50 of 1 Mb), and sequence accuracy (>98% of BUSCO genes without frameshift errors). This workflow has general utility for small-bodied insects and other plant and animal species for both focused research studies or in conjunction with large-scale genome projects.


June 1, 2021  |  

New advances in SMRT Sequencing facilitate multiplexing for de novo and structural variant studies

The latest advancements in Sequel II SMRT Sequencing have increased average read lengths up to 50% compared to Sequel II chemistry 1.0 which allows multiplexing of 2-3 small organisms (<500 Mb) such as insects and worms for producing reference quality assemblies, calling structural variants for up to 2 samples with ~3 Gb genomes, analysis of 48 microbial genomes, and up to 8 communities for metagenomic profiling in a single SMRT Cell 8M. With the improved processivity of the new Sequel II sequencing polymerase, more SMRTbell molecules reach rolling circle mode resulting in longer overall read lengths, thus allowing efficient detection of barcodes (up to 80%) in the SMRTbell templates. Multiplexing of genomes larger than microbial organisms is now achievable. In collaboration with the Wellcome Sanger Institute, we have developed a workflow for multiplexing two individual Anopheles coluzzii using as low as 150 ng genomic DNA per individual. The resulting assemblies had high contiguity (contig N50s over 3 Mb) and completeness (>98% of conserved genes) for both individuals. For microbial multiplexing, we multiplexed 48 microbes with varying complexities and sizes ranging 1.6-8.0 Mb in single SMRT Cell 8M. Using a new end-to-end analysis (Microbial Assembly Analysis, SMRT Link 8.0), assemblies resulted in complete circularized genomes (>200-fold coverage) and efficient detection of >3-200 kb plasmids. Finally, the long read lengths (>90 kb) allows detection of barcodes in large insert SMRTbell templates (>15 kb) thus facilitating multiplex of two human samples in 1 SMRT Cell 8M for detecting SVs, Indels and CNVs. Here, we present results and describe workflows for multiplexing samples for specific applications for SMRT Sequencing.


June 1, 2021  |  

Unbiased characterization of metagenome composition and function using HiFi sequencing on the PacBio Sequel II System

Recent work comparing metagenomic sequencing methods indicates that a comprehensive picture of the taxonomic and functional diversity of complex communities will be difficult to achieve with one sequencing technology alone. While the lower cost of short reads has enabled greater sequencing depth, the greater contiguity of long-read assemblies and lack of GC bias in SMRT Sequencing has enabled better gene finding. However, since long-read assembly typically requires high coverage for error correction, these benefits have in the past been lost for low-abundance species. The introduction of the Sequel II System has enabled a new, higher throughput, assembly-optional data type that addresses these challenges: HiFi reads. HiFi reads combine QV20 accuracy with long read lengths, eliminating the need for assembly for most metagenome applications, including gene discovery and metabolic pathway reconstruction. In fact, the read lengths and accuracy of HiFi data match or outperform the quality metrics of most metagenome assemblies, enabling cost-effective recovery of intact genes and operons while omitting the resource intensive and data-inefficient assembly step. Here we present the application of HiFi sequencing to both mock and human fecal samples using full-length 16S and shotgun methods. This proof-of-concept work demonstrates the unique strengths of the HiFi method. First, the high correspondence between the expected community composition,16S and shotgun profiling data reflects low context bias. In addition, every HiFi read yields ~5-8 predicted genes, without assembly, using standard tools. If assembly is desired, excellent results can be achieved with Canu and contig binning tools. In summary, HiFi sequencing is a new, cost-effective option for high-resolution functional profiling of metagenomes which complements existing short read workflows.


June 1, 2021  |  

Low-input single molecule HiFi sequencing for metagenomic samples

HiFi sequencing on the PacBio Sequel II System enables complete microbial community profiling of complex metagenomic samples using whole genome shotgun sequences. With HiFi sequencing, highly accurate long reads overcome the challenges posed by the presence of intergenic and extragenic repeat elements in microbial genomes, thus greatly improving phylogenetic profiling and sequence assembly. Recent improvements in library construction protocols enable HiFi sequencing starting from as low as 5 ng of input DNA. Here, we demonstrate comparative analyses of a control sample of known composition and a human fecal sample from varying amounts of input genomic DNA (1 ug, 200 ng, 5 ng), and present the corresponding library preparation workflows for standard, low input, and Ultra-Low methods. We demonstrate that the metagenome assembly, taxonomic assignment, and gene finding analyses are comparable across all methods for both samples, providing access to HiFi sequencing even for DNA-limited sample types.


Talk with an expert

If you have a question, need to check the status of an order, or are interested in purchasing an instrument, we're here to help.