X

Quality Statement

Pacific Biosciences is committed to providing high-quality products that meet customer expectations and comply with regulations. We will achieve these goals by adhering to and maintaining an effective quality-management system designed to ensure product quality, performance, and safety.

X

Image Use Agreement

By downloading, copying, or making any use of the images located on this website (“Site”) you acknowledge that you have read and understand, and agree to, the terms of this Image Usage Agreement, as well as the terms provided on the Legal Notices webpage, which together govern your use of the images as provided below. If you do not agree to such terms, do not download, copy or use the images in any way, unless you have written permission signed by an authorized Pacific Biosciences representative.

Subject to the terms of this Agreement and the terms provided on the Legal Notices webpage (to the extent they do not conflict with the terms of this Agreement), you may use the images on the Site solely for (a) editorial use by press and/or industry analysts, (b) in connection with a normal, peer-reviewed, scientific publication, book or presentation, or the like. You may not alter or modify any image, in whole or in part, for any reason. You may not use any image in a manner that misrepresents the associated Pacific Biosciences product, service or technology or any associated characteristics, data, or properties thereof. You also may not use any image in a manner that denotes some representation or warranty (express, implied or statutory) from Pacific Biosciences of the product, service or technology. The rights granted by this Agreement are personal to you and are not transferable by you to another party.

You, and not Pacific Biosciences, are responsible for your use of the images. You acknowledge and agree that any misuse of the images or breach of this Agreement will cause Pacific Biosciences irreparable harm. Pacific Biosciences is either an owner or licensee of the image, and not an agent for the owner. You agree to give Pacific Biosciences a credit line as follows: "Courtesy of Pacific Biosciences of California, Inc., Menlo Park, CA, USA" and also include any other credits or acknowledgments noted by Pacific Biosciences. You must include any copyright notice originally included with the images on all copies.

IMAGES ARE PROVIDED BY Pacific Biosciences ON AN "AS-IS" BASIS. Pacific Biosciences DISCLAIMS ALL REPRESENTATIONS AND WARRANTIES, EXPRESS, IMPLIED OR STATUTORY, INCLUDING, BUT NOT LIMITED TO, NON-INFRINGEMENT, OWNERSHIP, MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL Pacific Biosciences BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, PUNITIVE, OR CONSEQUENTIAL DAMAGES OF ANY KIND WHATSOEVER WITH RESPECT TO THE IMAGES.

You agree that Pacific Biosciences may terminate your access to and use of the images located on the PacificBiosciences.com website at any time and without prior notice, if it considers you to have violated any of the terms of this Image Use Agreement. You agree to indemnify, defend and hold harmless Pacific Biosciences, its officers, directors, employees, agents, licensors, suppliers and any third party information providers to the Site from and against all losses, expenses, damages and costs, including reasonable attorneys' fees, resulting from any violation by you of the terms of this Image Use Agreement or Pacific Biosciences' termination of your access to or use of the Site. Termination will not affect Pacific Biosciences' rights or your obligations which accrued before the termination.

I have read and understand, and agree to, the Image Usage Agreement.

I disagree and would like to return to the Pacific Biosciences home page.

Pacific Biosciences
お問い合わせ

Template preparation reagents for preparing and multiplexing SMRTbell library templates for long-read sequencing on the PacBio Sequel System.

Template preparation consumables

Quickly create libraries for Single Molecule, Real Time (SMRT) Sequencing with our template preparation kits. DNA is treated to ensure the removal of any DNA damage, and ends are repaired and circularized with the addition of SMRTbell adapters. The result is a circularized template, called a SMRTbell library.

SMRTbell templates provide a segment of single-stranded DNA to which a sequencing primer is annealed. A polymerase is bound to a primer-annealed template and the complex is ready to be loaded onto SMRT Cells.

SMRTbell Express Template Prep KitPN: 101-357-000

Quickly prepare long-insert SMRTbell libraries for the Sequel System.

Product Details

SMRTbell Template Prep Kit 1.0-SPv3PN: 100-991-900

Prepare primer-annealed, symmetric SMRTbell libraries for insert sizes ranging from 500 bp to over 20 kb.

Product Details

AMPure PBPN: 100-265-900

Magnetic beads specifically formulated for the removal of 1) small template fragments during the template preparation or 2) excess polymerase and primer from polymerase-bound SMRTbell complexes.

Product Details

Multiplexing consumables

Sequence multiple samples on the same SMRT Cell to increase throughput and enhance the efficiency of your research. Multiplexing is supported with three barcoding options providing flexibility to incorporate unique sample identifiers during target amplification or library preparation.

Illustrations of barcoded primers, barcoded universal primers, and barcoded adaptors.

  • Add barcoded primers to amplicons during (1) PCR through either target-specific primers with incorporated barcodes or (2) a two-step PCR using barcoded universal primers.
  • Add barcodes to samples with (3) ligation of barcoded SMRTbell adapters to template.

Learn more about Multiplexing, including information on barcode sequences compatible with SMRT Sequencing.

Barcoded Adapter Kit -8A/BPN: 101-081-300/400

Two sets of 8 barcoded adapters for multiplexing SMRTbell libraries in applications such as multiplexing for microbial whole genome sequencing.

Product Details

Barcoded Universal F/R Primers Plate -96PN: 100-466-100

A set of 96 barcoded primer pairs for multiplexing amplicons containing universal sequence tags.

Product Details

SMRTbell Barcoded Adapter Complete Prep -96PN: 100-514-900

A set of 96 barcoded SMRTbell adapters for multiplexing amplicons through ligation to generate SMRTbell libraries and do not require modifications to existing, pre-designed PCR primers.

Product Details

SMRTbell Damage Repair Kit -SPv3PN: 100-992-200

Perform DNA damage repair, Exonuclease III and VII treatments, and primer annealing of SMRTbell libraries prepared with SMRTbell barcoded adapters.

Product Details

Find information on Sample and Preparation Kits for PacBio RS II

 