June 1, 2021  |  

A simple segue from Sanger to high-throughput SMRT Sequencing with a M13 barcoding system

High-throughput NGS methods are increasingly utilized in the clinical genomics market. However, short-read sequencing data continues to remain challenged by mapping inaccuracies in low complexity regions or regions of high homology and may not provide adequate coverage within GC-rich regions of the genome. Thus, the use of Sanger sequencing remains popular in many clinical sequencing labs as the gold standard approach for orthogonal validation of variants and to interrogate missed regions poorly covered by second-generation sequencing. The use of Sanger sequencing can be less than ideal, as it can be costly for high volume assays and projects. Additionally, Sanger sequencing generates read lengths shorter than the region of interest, which limits its ability to accurately phase allelic variants. High-throughput SMRT Sequencing overcomes the challenges of both the first- and second-generation sequencing methods. PacBio’s long read capability allows sequencing of full-length amplicons


June 1, 2021  |  

Comprehensive variant detection in a human genome with PacBio high-fidelity reads

Human genomic variations range in size from single nucleotide substitutions to large chromosomal rearrangements. Sequencing technologies tend to be optimized for detecting particular variant types and sizes. Short reads excel at detecting SNVs and small indels, while long or linked reads are typically used to detect larger structural variants or phase distant loci. Long reads are more easily mapped to repetitive regions, but tend to have lower per-base accuracy, making it difficult to call short variants. The PacBio Sequel System produces two main data types: long continuous reads (up to 100 kbp), generated by single passes over a long template, and Circular Consensus Sequence (CCS) reads, generated by calculating the consensus of many sequencing passes over a single shorter template (500 bp to 20 kbp). The long-range information in continuous reads is useful for genome assembly and structural variant detection. The higher base accuracy of CCS effectively detects and phases short variants in single molecules. Recent improvements in library preparation protocols and sequencing chemistry have increased the length, accuracy, and throughput of CCS reads. For the human sample HG002, we collected 28-fold coverage 15 kbp high-fidelity CCS reads with an average read quality above Q20 (99% accuracy). The length and accuracy of these reads allow us to detect SNVs, indels, and structural variants not only in the Genome in a Bottle (GIAB) high confidence regions, but also in segmental duplications, HLA loci, and clinically relevant “difficult-to-map” genes. As with continuous long reads, we call structural variants at 90.0% recall compared to the GIAB structural variant benchmark “truth” set, with the added advantages of base pair resolution for variant calls and improved recall at compound heterozygous loci. With minimap2 alignments, GATK4 HaplotypeCaller variant calls, and simple variant filtration, we have achieved a SNP F-Score of 99.51% and an INDEL F-Score of 80.10% against the GIAB short variant benchmark “truth” set, in addition to calling variants outside of the high confidence region established by GIAB using previous technologies. With the long-range information available in 15 kbp reads, we applied the read-backed phasing tool WhatsHap to generate phase blocks with a mean length of 65 kbp across the entire genome. Using an alignment-based approach, we typed all major MHC class I and class II genes to at least 3-field precision. This new data type has the potential to expand the GIAB high confidence regions and “truth” benchmark sets to many previously difficult-to-map genes and allow a single sequencing protocol to address both short variants and large structural variants.


June 1, 2021  |  

Single molecule high-fidelity (HiFi) Sequencing with >10 kb libraries

Recent improvements in sequencing chemistry and instrument performance combine to create a new PacBio data type, Single Molecule High-Fidelity reads (HiFi reads). Increased read length and improvement in library construction enables average read lengths of 10-20 kb with average sequence identity greater than 99% from raw single molecule reads. The resulting reads have the accuracy comparable to short read NGS but with 50-100 times longer read length. Here we benchmark the performance of this data type by sequencing and genotyping the Genome in a Bottle (GIAB) HG0002 human reference sample from the National Institute of Standards and Technology (NIST). We further demonstrate the general utility of HiFi reads by analyzing multiple clones of Cabernet Sauvignon. Three different clones were sequenced and de novo assembled with the CANU assembly algorithm, generating draft assemblies of very high contiguity equal to or better than earlier assembly efforts using PacBio long reads. Using the Cabernet Sauvignon Clone 8 assembly as a reference, we mapped the HiFi reads generated from Clone 6 and Clone 47 to identify single nucleotide polymorphisms (SNPs) and structural variants (SVs) that are specific to each of the three samples.


June 1, 2021  |  

Comprehensive variant detection in a human genome with highly accurate long reads

Introduction: Long-read sequencing has been applied successfully to assemble genomes and detect structural variants. However, due to high raw-read error rates (10-15%), it has remained difficult to call small variants from long reads. Recent improvements in library preparation and sequencing chemistry have increased length, accuracy, and throughput of PacBio circular consensus sequencing (CCS) reads, resulting in 10-20kb reads with average read quality above 99%. Materials and Methods: We sequenced a 12kb library from human reference sample HG002 to 18-fold coverage on the PacBio Sequel II System with three SMRT Cells 8M. The CCS algorithm was used to generate highly-accurate (average 99.8%) 11.4kb reads, which were mapped to the hg19 reference with pbmm2. We detected small variants using Google DeepVariant with a model trained for CCS and phased the variants using WhatsHap. Structural variants were detected with pbsv. Variant calls were evaluated against Genome in a Bottle (GIAB) benchmarks. Results: With these reads, DeepVariant achieves SNP and Indel F1 scores of 99.82% and 96.70% against the GIAB truth set, and pbsv achieves 95.94% recall on structural variants longer than 50bp. Using WhatsHap, small variants were phased into haplotype blocks with 105kb N50. The improved mappability of long reads allows us to align to and detect variants in medically relevant genes such as CYP2D6 and PMS2 that have proven “difficult-to-map” with short reads. Conclusions: These highly-accurate long reads combine the mappability and ability to detect structural variants of long reads with the accuracy and ability to detect small variants of short reads.


June 1, 2021  |  

Comparison of sequencing approaches applied to complex soil metagenomes to resolve proteins of interest

Background: Long-read sequencing presents several potential advantages for providing more complete gene profiling of metagenomic samples. Long reads can capture multiple genes in a single read, and longer reads typically result in assemblies with better contiguity, especially for higher abundance organisms. However, a major challenge with using long reads has been the higher cost per base, which may lead to insufficient coverage of low-abundance species. Additionally, lower single-pass accuracy can make gene discovery for low-abundance organisms difficult. Methods: To evaluate the pros and cons of long reads for metagenomics, we directly compared PacBio and Illumina sequencing on a soil-derived sample, which included spike-in controls of known concentrations of pure referenced samples. For PacBio sequencing, a 10 kb library was sequenced on the Sequel System with 3.0 chemistry. Highly accurate long reads (HiFi reads) with Q20 and higher were generated for downstream analyses using PacBio Circular Consensus Sequencing (CCS) mode. Results were assessed according to the following criteria: DNA extraction capacity, bioinformatics pipeline status, % of proteins with ambiguous AA’s, total unique error-free genes/$1000, total proteins observed in spike-ins/$1000, proteins of interest/$1000, median length of contigs with proteins, and assembly requirements. Results: Both methods had areas of superior performance. DNA extraction capacity was higher for Illumina, the bioinformatics pipeline is well-tested, and there was a lower proportion of proteins with ambiguous AA’s. On the other hand, with PacBio, twice as many unique error-free genes, twice as many total proteins from spike-ins, and ~6 times more proteins of interest were found per $1000 cost. PacBio data produced on average 5 times longer contigs capturing proteins of interest. Additionally, assembly was not required for gene or protein finding, as was the case with Illumina data. Conclusions: In this comparison of PacBio Sequel System with Illumina NextSeq on a complex microbiome, we conclude that the sequencing system of choice may vary, depending on the goals and resources for the project. PacBio sequencing requires a longer DNA extraction method, and the bioinformatics pipeline may require development. On the other hand, the Sequel System generates hundreds of thousands of long HiFi reads per SMRT Cell, producing more genes, more proteins, and longer contigs, thereby offering more information about the metagenomic samples for a lower cost.


June 1, 2021  |  

Unbiased characterization of metagenome composition and function using HiFi sequencing on the PacBio Sequel II System

Recent work comparing metagenomic sequencing methods indicates that a comprehensive picture of the taxonomic and functional diversity of complex communities will be difficult to achieve with short-read technology alone. While the lower cost of short reads has enabled greater sequencing depth, the greater contiguity of long-read assemblies and lack of GC bias in SMRT Sequencing has enabled better gene finding. However, since long-read assembly requires high coverage for error correction, the benefits of unbiased coverage have in the past been lost for low abundance species. SMRT Sequencing performance improvements and the introduction of the Sequel II System has enabled a new, high throughput data type uniquely suited to metagenome characterization: HiFi reads. HiFi reads combine high accuracy with read lengths up to 15 kb, eliminating the need for assembly for most microbiome applications, including functional profiling, gene discovery, and metabolic pathway reconstruction. Here we present the application of the HiFi data type to enable a new method of analyzing metagenomes that does not require assembly.


June 1, 2021  |  

Sequencing the previously unsequenceable using amplification-free targeted enrichment powered by CRISPR/Cas9

Genomic regions with extreme base composition bias and repetitive sequences have long proven challenging for targeted enrichment methods, as they rely upon some form of amplification. Similarly, most DNA sequencing technologies struggle to faithfully sequence regions of low complexity. This has especially been true for repeat expansion disorders such as Fragile X syndrome, Huntington’s disease and various Ataxias, where the repetitive elements range from several hundreds of bases to tens of kilobases. We have developed a robust, amplification-free targeted enrichment technique, called No-Amp Targeted Sequencing, that employs the CRISPR/Cas9 system. In conjunction with Single Molecule, Real-Time (SMRT) Sequencing, which delivers long reads spanning the entire repeat expansion, high consensus accuracy, and uniform coverage, these previously inaccessible regions are now accessible. This method is completely amplification-free, therefore removing any PCR errors and biases from the experiment. Furthermore, this technique also preserves native DNA molecules, allowing for direct detection and characterization of epigenetic signatures. The No-Amp method is a two-day protocol, compatible with multiplexing of multiple targets and samples in a single reaction, using as little as 1 µg of genomic DNA input per sample. We have successfully targeted a number of repeat expansion disorder loci (HTT, FMR1, ATXN10, C9orf72) with alleles as long as >2700 repeat unites (>13 kb). Using the No-Amp method we have isolated hundreds of individual on-target molecules, allowing for reliable repeat size estimation, mosaicism detection and identification of interruption sequences – all aspects of repeat expansion disorders which are important for better understanding the underlying disease mechanisms.


June 1, 2021  |  

The value of long read amplicon sequencing for clinical applications

NGS is commonly used for amplicon sequencing in clinical applications to study genetic disorders and detect disease-causing mutations. This approach can be plagued by limited ability to phase sequence variants and makes interpretation of sequence data difficult when pseudogenes are present. Long-read highly accurate amplicon sequencing can provide very accurate, efficient, high throughput (through multiplexing) sequences from single molecules, with read lengths largely limited by PCR. Data is easy to interpret; phased variants and breakpoints are present within high fidelity individual reads. Here we show SMRT Sequencing of the PMS2 and OPN1 (MW and LW) genes using the Sequel System. Homologous regions make NGS and MLPA results very difficult to interpret.


June 1, 2021  |  

TLA & long-read sequencing: Efficient targeted sequencing and phasing of the CFTR gene

Background: The sequencing and haplotype phasing of entire gene sequences improves the understanding of the genetic basis of disease and drug response. One example is cystic fibrosis (CF). Cystic fibrosis transmembrane conductance regulator (CFTR) modulator therapies have revolutionized CF treatment, but only in a minority of CF subjects. Observed heterogeneity in CFTR modulator efficacy is related to the range of CFTR mutations; revertant mutations can modify the response to CFTR modulators, and other intronic variations in the ~200 kb CFTR gene have been linked to disease severity. Heterogeneity in the CFTR gene may also be linked to differential responses to CFTR modulators. The Targeted Locus Amplification (TLA) technology from Cergentis can be used to selectively amplify, sequence and phase the entire CFTR gene. With PacBio long-read SMRT Sequencing, TLA amplicons are sequenced intact and long-range phasing information of all fragments in entire amplicons is retrieved. Experimental Design and Methods: The TLA process produces amplicons consisting of 5-10 proximity ligated DNA fragments. TLA was performed on cell line and genomic DNA from Coriell GM12878, which has few heterozygous SNVs in CFTR, and the IB3 cell line, with known haplotypes but heterozygous for the delta508 mutation. All sample types were prepared with high and low density TLA primer sets, targeting coverage of >100 kb of the CFTR gene. Conclusion: We have demonstrated the power and utility of TLA with long-read SMRT Sequencing as a valuable research tool in sequencing and phasing across very long regions of the human genome. This process can be done in an efficient manner, multiplexing multiple genes and samples per SMRT Cell in a process amenable to high-throughput sequencing.


June 1, 2021  |  

High-quality human genomes achieved through HiFi sequence data and FALCON-Unzip assembly

De novo assemblies of human genomes from accurate (85-90%), continuous long reads (CLR) now approach the human reference genome in contiguity, but the assembly base pair accuracy is typically below QV40 (99.99%), an order-of-magnitude lower than the standard for finished references. The base pair errors complicate downstream interpretation, particularly false positive indels that lead to false gene loss through frameshifts. PacBio HiFi sequence data, which are both long (>10 kb) and very accurate (>99.9%) at the individual sequence read level, enable a new paradigm in human genome assembly. Haploid human assemblies using HiFi data achieve similar contiguity to those using CLR data and are highly accurate at the base level1. Furthermore, HiFi assemblies resolve more high-identity sequences such as segmental duplications2. To enable HiFi assembly in diploid human samples, we have extended the FALCON-Unzip assembler to work directly with HiFi reads. Here we present phased human diploid genome assemblies from HiFi sequencing of HG002, HG005, and the Vertebrate Genome Project (VGP) mHomSap1 trio on the PacBio Sequel II System. The HiFi assemblies all exceed the VGP’s quality guidelines, approaching QV50 (99.999%) accuracy. For HG002, 60% of the genome was haplotype-resolved, with phase-block N50 of 143Kbp and phasing accuracy of 99.6%. The overall mean base accuracy of the assembly was QV49.7. In conclusion, HiFi data show great promise towards complete, contiguous, and accurate diploid human assemblies.