+

X

Quality Statement

Pacific Biosciences is committed to providing high-quality products that meet customer expectations and comply with regulations. We will achieve these goals by adhering to and maintaining an effective quality-management system designed to ensure product quality, performance, and safety.

X

Image Use Agreement

By downloading, copying, or making any use of the images located on this website (“Site”) you acknowledge that you have read and understand, and agree to, the terms of this Image Usage Agreement, as well as the terms provided on the Legal Notices webpage, which together govern your use of the images as provided below. If you do not agree to such terms, do not download, copy or use the images in any way, unless you have written permission signed by an authorized Pacific Biosciences representative.

Subject to the terms of this Agreement and the terms provided on the Legal Notices webpage (to the extent they do not conflict with the terms of this Agreement), you may use the images on the Site solely for (a) editorial use by press and/or industry analysts, (b) in connection with a normal, peer-reviewed, scientific publication, book or presentation, or the like. You may not alter or modify any image, in whole or in part, for any reason. You may not use any image in a manner that misrepresents the associated Pacific Biosciences product, service or technology or any associated characteristics, data, or properties thereof. You also may not use any image in a manner that denotes some representation or warranty (express, implied or statutory) from Pacific Biosciences of the product, service or technology. The rights granted by this Agreement are personal to you and are not transferable by you to another party.

You, and not Pacific Biosciences, are responsible for your use of the images. You acknowledge and agree that any misuse of the images or breach of this Agreement will cause Pacific Biosciences irreparable harm. Pacific Biosciences is either an owner or licensee of the image, and not an agent for the owner. You agree to give Pacific Biosciences a credit line as follows: "Courtesy of Pacific Biosciences of California, Inc., Menlo Park, CA, USA" and also include any other credits or acknowledgments noted by Pacific Biosciences. You must include any copyright notice originally included with the images on all copies.

IMAGES ARE PROVIDED BY Pacific Biosciences ON AN "AS-IS" BASIS. Pacific Biosciences DISCLAIMS ALL REPRESENTATIONS AND WARRANTIES, EXPRESS, IMPLIED OR STATUTORY, INCLUDING, BUT NOT LIMITED TO, NON-INFRINGEMENT, OWNERSHIP, MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL Pacific Biosciences BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, PUNITIVE, OR CONSEQUENTIAL DAMAGES OF ANY KIND WHATSOEVER WITH RESPECT TO THE IMAGES.

You agree that Pacific Biosciences may terminate your access to and use of the images located on the PacificBiosciences.com website at any time and without prior notice, if it considers you to have violated any of the terms of this Image Use Agreement. You agree to indemnify, defend and hold harmless Pacific Biosciences, its officers, directors, employees, agents, licensors, suppliers and any third party information providers to the Site from and against all losses, expenses, damages and costs, including reasonable attorneys' fees, resulting from any violation by you of the terms of this Image Use Agreement or Pacific Biosciences' termination of your access to or use of the Site. Termination will not affect Pacific Biosciences’ rights or your obligations which accrued before the termination.

I have read and understand, and agree to, the Image Usage Agreement.

I disagree and would like to return to the Pacific Biosciences home page.

Pacific Biosciences
Contact:

SMRT Cells, Sequencing Reagent Kits, and Accessories for the Sequel System

SMRT Cells, DNA Sequencing Reagent Kits, and accessories support automated SMRT Sequencing on the Sequel System.

 

Sequel SMRT Cell 1M v2 Tray (4 cells)

101-008-000
The Sequel SMRT Cell 1M v2 Tray (4 cells) are nanofabricated consumables each patterned with 1,000,000 wells called zero-mode waveguides (ZMWs). They are packaged together in a streamlined 4 SMRT Cell format. SMRT Cell 1M v2 is compatible with Sequel Binding Kit 2.0 and Sequel Sequencing Kit 2.0. One SMRT Cell 1M is utilized in each sequencing reaction, and experiments can be run on a single or in batch mode, giving your projects a greater level of flexibility.

Insert: Sequel SMRT Cell 1M
SDS: Sequel SMRT Cell 1M v2

Please refer to the Sequel System manual.

Sequel Sequencing Kit 2.0

101-011-000
The Sequel Sequencing Kit 2.0 (8rxn) contains a sequencing reagent plate with Sequel Sequencing chemistry 2.0 and a tube of Sequel Oxygen Scavenging (OS) Enzyme for SMRT Sequencing on the Sequel System. Reagent quantities support 8 sequencing reactions. The Sequel Sequencing Kit 2.0 to be used with a Sequel SMRT Cell 1M v2. Sequel Sequencing Kit 2.0 is only compatible with templates bound to Sequel DNA Polymerase 2.0.
Please refer to the Sequel System operation manual.

Sequel Sequencing Kit 2.0 bundle (5 pack)

101-053-000
The Sequel Sequencing 2.0 Bundle (5 pack) contains reagent and disposable supplies for 40 reactions of SMRT Sequencing. It contains 5 Sequel Sequencing Kits 2.0, 1 Sequel SMRT Cell Oil pack, and 1 Tube Septa pack.

Insert: Sequel Sequencing Kit 2.0
Insert: SMRT Cell Oil
SDS: Sequel Sequencing Kit 2.0
SDS: SMRT Cell Oil / Sequel SMRT Cell Oil

Please refer to the Sequel System operation manual.

Sequel SMRT Cell Oil

100-619-600
Sequel SMRT Cell Oil contains 5 reagent tubes for SMRT Sequencing on the Sequel System (used with the Sequel Sequencing Kit). Reagent quantities support 5 sequencing runs.
Please refer to the Sequel System operation manual.

Sequencing controls

Sequencing Controls are either used as an internal control added your polymerase-bound SMRTbell template or a control used on an individual SMRT Cell.

Sequel DNA Internal Control 1.0

100-619-900
The Sequel DNA Internal Control 1.0 contains a fixed template of 2 kb length bound to Sequel Polymerase 1.0 for use as an internal sequencing control. Reagent quantities provide spike-in controls for a minimum of 24 samples.

Sequel SMRT Cell Control Complex 1.0

100-620-100
The Sequel SMRT Cell Control Complex 1.0 contains Lambda library DNA template sheared to a peak size of 2 kb and bound to Sequel Polymerase 1.0. It acts as a complete Sequel SMRT Cell control.

For more information about how our Sequel System consumables can support your research, contact us.

Event

Dutch Society of Human Genetics Meeting (NVHG) 2017

September 21 - September 22, 2017

Stay
Current

Visit our blog »